+8613631697416
SF6 Gas Dew point Purity Decomposition Tester
- Mass storage function
- Battery level reminder
- Good repeatability and fast response speed
- Touch operation instrument
- Large-screen color LCD display
- Advanced probe protection
- Anti-pollution and anti-interference
- High sensitivity and good stability
- Small and beautiful, easy to carry
10.Intuitive curve display
- The micro water value is automatically converted into a standard micro
water value of 20 ℃
描述
SF6 Gas Dew point Purity Decomposition Tester
Introduction
SF6 Gas Analyzer adopts the humidity sensor, purity, SO2, H2S, CO and other sensors of Finland VAISALA company. The thermal conductivity sensor and electrochemical sensor of British ALPHA company are used; at the same time, it is equipped with the most advanced ARM development technology and quality Precision sensors such as flow sensors and temperature sensors make sampling data more realistic, more reliable, and faster in calculation speed. The instrument uses a color liquid crystal display screen, the interface is user friendly , easy to operate.
Features
- Mass storage function
- Battery level reminder
- Good repeatability and fast response speed
- Touch operation instrument
- Large-screen color LCD display
- Advanced probe protection
- Anti-pollution and anti-interference
- High sensitivity and good stability
- Small and beautiful, easy to carry
10.Intuitive curve display
- The micro water value is automatically converted into a standard micro
water value of 20 ℃
Technical index:
1. Measuring range: dew point -60℃ ~ +20℃ (support ppmv etc.)
2. Dew point accuracy: The test accuracy is better than ±0.5℃ (within a certain range) (When the dew point temperature is lower than 0℃, the sensor output is frost point) 3. Response time63%[90%] +20→-20℃ Td 5s[45s] -20→-60℃ Td 10s[240s] 4. Resolution: Dew point 0.1℃ or 0.1ppm 5. Repeatability: ±0.2℃ 6. Measurement range of gas decomposition products: SO2:0 ~ 100 µl/l H2S:0 ~ 100 µl/l CO: 0 ~ 500 µl/l HF: 0~10ppm7. Sensitivity:SO2:±0.5µl/l H2S:±0.5µl/l CO:±1µl/l HF: 0.1µl/l 8. SF6 gas purity measurement range:0 ~ 99.99 % 9. Measurement accuracy: within 90%~99.99%, the error ≤±0.1% 10.Gas flow: Flow adjustment A is adjusted at 0.2L/min Flow adjustment B is adjusted to 0.5-0.6L/min 11. Probe protection: stainless steel sintered filter 12.Working voltage:110~220VAC 13.Storage temperature grade:-40~+70℃ 14.Operating environment:Temperature:-35~+60℃ Pressure:0~20bar Sample gas flow rate: no effect 15.Electronic mass flow meter |