SF6 Gas Dew point Purity Decomposition Tester

  1. Mass storage function
  2. Battery level reminder
  3. Good repeatability and fast response speed
  4. Touch operation instrument
  5. Large-screen color LCD display
  6. Advanced probe protection
  7. Anti-pollution and anti-interference
  8. High sensitivity and good stability
  9. Small and beautiful, easy to carry

10.Intuitive curve display

  1. The micro water value is automatically converted into a standard micro

water value of 20 ℃

分类:

描述

SF6 Gas Dew point Purity Decomposition Tester

Introduction

SF6 Gas Analyzer adopts the humidity sensor, purity, SO2, H2S, CO and other sensors of Finland VAISALA company. The thermal conductivity sensor and electrochemical sensor of British ALPHA company are used; at the same time, it is equipped with the most advanced ARM development technology and quality Precision sensors such as flow sensors and temperature sensors make sampling data more realistic, more reliable, and faster in calculation speed. The instrument uses a color liquid crystal display screen, the interface is user friendly , easy to operate.

Features

  1. Mass storage function
  2. Battery level reminder
  3. Good repeatability and fast response speed
  4. Touch operation instrument
  5. Large-screen color LCD display
  6. Advanced probe protection
  7. Anti-pollution and anti-interference
  8. High sensitivity and good stability
  9. Small and beautiful, easy to carry

10.Intuitive curve display

  1. The micro water value is automatically converted into a standard micro

water value of 20 ℃

 

Technical index:

1. Measuring range: dew point -60℃ ~ +20℃ (support ppmv etc.)

2. Dew point accuracy: The test accuracy is better than ±0.5℃ (within a

certain range)

(When the dew point temperature is lower than 0℃, the sensor output is frost

point)

3. Response time63%[90%]

+20→-20℃

Td 5s[45s]

-20→-60℃

Td 10s[240s]

4. Resolution: Dew point 0.1℃ or 0.1ppm

5. Repeatability: ±0.2℃

6. Measurement range of gas decomposition products:

SO2:0 ~ 100 µl/l

H2S:0 ~ 100 µl/l

CO: 0 ~ 500 µl/l

HF: 0~10ppm7. Sensitivity:SO2:±0.5µl/l

H2S:±0.5µl/l

CO:±1µl/l

HF: 0.1µl/l

8. SF6 gas purity measurement range:0 ~ 99.99 %

9. Measurement accuracy: within 90%~99.99%, the error ≤±0.1%

10.Gas flow: Flow adjustment A is adjusted at 0.2L/min

Flow adjustment B is adjusted to 0.5-0.6L/min

11. Probe protection: stainless steel sintered filter

12.Working voltage:110~220VAC

13.Storage temperature grade:-40~+70℃

14.Operating environment:Temperature:-35~+60℃

Pressure:0~20bar

Sample gas flow rate: no effect

15.Electronic mass flow meter

评价

目前还没有评价

成为第一个“SF6 Gas Dew point Purity Decomposition Tester” 的评价者

您的电子邮箱地址不会被公开。 必填项已用 * 标注